Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licenseReconocimiento-NoComercial-SinObraDerivada 4.0 Internacional. (CC BY-NC-ND)-
dc.contributor.authorLujan, Lautaroes
dc.contributor.authorTejera, Gonzaloes
dc.contributor.authorSuárez, Milagroses
dc.contributor.authorCorrea Perelmuter, Gabrieles
dc.contributor.authorDíaz, Verónicaes
dc.date.accessioned2026-11-04T14:33:45Z-
dc.date.issued2026-10-07-
dc.identifier.urihttps://hdl.handle.net/20.500.12381/5748-
dc.description.abstractAccurate zero-dimensional models of proton exchange membrane water electrolysis are valuable for stack design, technoeconomic analysis, and system level simulation, but their predictive capability is often limited by the use of parameters obtained from full-cell curve fitting. This work presents a multiphysics lumped model of a single PEM water electrolyzer cell that combines thermodynamics, electrode polarization, mass transport, ohmic losses, and bubble-related effects. A three-electrode configuration incorporating a palladium hydride wire reference electrode was used to resolve the anodic and cathodic polarization responses independently, while full-cell and membrane-free electrochemical impedance spectroscopy were employed to estimate the membrane and lumped electronic/contact resistances. The electrode specific Tafel parameters were introduced into the model as effective descriptors of the porous-electrode response rather than as intrinsic elementary kinetic constants, particularly for the cathode, where the measured slopes were influenced by the coupled effects of HER/HOR kinetics, local hydrogen accumulation, and catalyst-layer transport. Using a single parameter set, the model reproduced the measured polarization curves at 25, 40, and 70 °C without temperaturespecific adjustment, with mean relative absolute deviations below 1%. Anodic activation losses dominate at low current density (up to 70% of the total overpotential), while ohmic and bubble-induced losses become increasingly significant at high current density, with anodic bubble coverage reaching approximately 31%. A global sensitivity analysis identifies membrane hydration and exchange current densities as the parameters governing model uncertainty. The framework provides a validated, physically grounded kernel for predictive PEM electrolyzer design and system level studies.es
dc.description.sponsorshipAgencia Nacional de Investigacion e Innovaciónes
dc.language.isoenges
dc.publisherElsevieres
dc.relationhttps://hdl.handle.net/20.500.12381/5743es
dc.relationhttps://hdl.handle.net/20.500.12381/5744es
dc.relationhttps://hdl.handle.net/20.500.12381/5307es
dc.relationhttps://hdl.handle.net/20.500.12381/5318es
dc.relationhttps://hdl.handle.net/20.500.12381/5498es
dc.relationhttps://hdl.handle.net/20.500.12381/5499es
dc.relationhttps://hdl.handle.net/20.500.12381/5500es
dc.relationhttps://hdl.handle.net/20.500.12381/5566es
dc.relationhttps://hdl.handle.net/20.500.12381/5601es
dc.relationhttps://hdl.handle.net/20.500.12381/5315es
dc.relationhttps://hdl.handle.net/20.500.12381/5749-
dc.relationhttps://hdl.handle.net/20.500.12381/5745-
dc.rightsAcceso embargado*
dc.sourceComputers and Chemical Engineeringes
dc.subjectPEM water electrolysises
dc.subjectLumped-parameter modeles
dc.subjectTafel kineticses
dc.subjectReference electrodees
dc.subjectElectrochemical impedance spectroscopyes
dc.subjectMultiphysics modelinges
dc.titleElectrode-resolved experimental parameterization of a multiphysics lumped model for PEM water electrolysises
dc.typeArtículoes
dc.subject.aniiIngeniería y Tecnología-
dc.subject.aniiOtras Ingenierías y Tecnologías-
dc.identifier.aniiPHV_X_2024_1_184611es
dc.type.versionAceptadoes
dc.rights.embargoend2028-10-06*
dc.rights.embargoreasonCondiciones revista*
dc.identifier.doi10.1016/j.compchemeng.2026.109916-
dc.anii.institucionresponsableUniversidad de la República, Facultad de Ingenieríaes
dc.rights.embargoterm2028-10-06*
dc.anii.subjectcompleto//Ingeniería y Tecnología/Otras Ingenierías y Tecnologías/Otras Ingenierías y Tecnologíases
Aparece en las colecciones: Publicaciones de ANII

Archivos en este ítem:
archivo  Descripción Tamaño Formato
Manuscript Lujan et al.pdf
  Fecha de fin de embargo: 2028-10-06
Descargar  Solicitar una copia1.4 MBAdobe PDF
Supplementary Material Lujan et al.pdf
  Fecha de fin de embargo: 2028-10-06
Descargar  Solicitar una copia1.01 MBAdobe PDF

Las obras en REDI están protegidas por licencias Creative Commons.
Por más información sobre los términos de esta publicación, visita: Reconocimiento-NoComercial-SinObraDerivada 4.0 Internacional. (CC BY-NC-ND)